Configuring MG Near-Match Settings

Use the following settings to configure how Synapse displays mammography images. Synapse also supports MG tomosynthesis series.

Path

Settings > Mammography > MG Near-Match

Steps

  1. Modify the following settings as needed.
  2. Optional: When you finish configuring all settings, click Close.

Top

MG Auto Compare and Extra Series Settings

MG Stack Settings

You can configure the following MG Stack settings for mammography studies in the MG Near-Match settings section:

 

MG Stack Match Priority

Setting

Description

Make the series-stacking protocols higher priority than the same-series protocols

  • If selected, Synapse determines the reading protocol priority for MG stacking.
  • This setting is selected by default.

Top

MG Stack Near-Match

Setting

Description

Enable stack near-match

  • If selected, Synapse activates additional MG Stack Near-Match options.
  • This setting is selected by default.

Top

Current Studies Near-Match Boundaries

Setting

Description

Maximum number of empty protocol stacks

  • Use this setting to specify the maximum number of MG stacks defined in a reading protocol that can be empty for the current study.
  • If applicable, select a different number from the drop-down list of 1 through 6.
  • The default setting is 3.

Maximum number of extra series stacks

  • Use this setting to specify the maximum number of MG stacks that Synapse would not display by a reading protocol for a current study.
  • If applicable, select a different number from the drop-down list of 1 through 6.
  • The default setting is 3.

Top

Prior Studies Near-Match Boundaries

Setting

Description

Maximum number (scaled) of empty protocol stacks

  • Use this setting to specify the maximum number of empty protocol stacks displayed for prior studies.
  • If applicable, select a different number from the drop-down list of 1 through 6.
  • The default setting is 6.

Maximum number of (scaled) of extra series stacks

  • Use this setting to specify the maximum number of extra study stacks displayed for prior studies.
  • If applicable, select a different number from the drop-down list of 1 through 6.
  • The default setting is 6.

Top

MG Stack 'All Priors' Sort

Setting

Description

Stack studies in acquired order, most recent to oldest

  • If selected, Synapse displays the newest study first and the oldest study last in the stack.
  • This setting is selected by default.

Stack studies in acquired order, oldest to most recent

  • If selected, Synapse displays the oldest study first and the newest study last in the stack.

Top

MG Near-Match Settings

You can configure the following settings in the MG Near-Match settings section:

Note:

Near-match settings only apply to Synapse 4.x-based Same Series reading protocols.

Setting

Description

Enable near-match

  • If selected, Synapse displays the following additional MG Near-Match settings.
  • This setting is selected by default.

Top

Near-Match Rules

Setting

Description

Near-match series, same procedure code

  • If selected, Synapse displays matching reading protocols for studies that have the same procedure code, but considers near-match series boundaries. The number of series can be different as configured in the Near-Match Series Boundaries settings.
  • This setting is selected by default.

Any series, same procedure code

  • If selected, Synapse displays matching reading protocols for studies that have the same procedure code, but does not consider near-match series boundaries.

Near-match series, any procedure code

  • If selected, Synapse displays reading protocols that ignore the procedure code, but considers near-match series boundaries. The number of series can be different as configured in the Near-Match Series Boundaries settings.
  • This setting is selected by default.

Top

Near-Match Series Boundaries

Setting

Description

Number of series more than reading protocol

  • If selected, Synapse specifies how many additional series can be in a study for Synapse to display a study using a series-based reading protocol that has a defined number of series with specific names. Synapse displays these extra series as additional steps.
  • If applicable, select a different number from the drop-down list of 1 through 6.
  • The default setting is 3.

Number of series less than reading protocol

  • If selected, Synapse specifies how many fewer series can be in a study for Synapse to display that study using a series-based reading protocol that has a defined number of series with specific names. Synapse displays blank viewports for missing series.
  • If applicable, select a different number from the drop-down list of 1 through 6.
  • The default setting is 3.

Top

Results

Synapse automatically saves any updated options and displays the following message in the bottom left corner of the window: Successfully saved.

Synapse displays the following message to alert you that an action must be taken for the settings to apply: Refresh the Synapse browser window for settings to apply.

Top

Related Topics

Configuring Mammography Settings

Configuring Cine Settings

Using Cine

Image and Series Sorting